Supports a variety of energy storage architectures
·Centralized Operation.
·Distributed Operation.
Flexible DC connection for parallel operation or distributed operation for each battery cluster.
Compared to standard market offerings of 20ft solution with 3~3.5MWh capacity, we are able to deliver 50% more capacity.
We develop liquid cooling for BESS thermal management. Advanced cooling technology options available to upgrade the system with free cooling and thermal storage. Further with our unique dispatching operation, the system can provide industry leading Round Trip Efficiency (RTE) up to 97%.
·Centralized Operation.
·Distributed Operation.
The series-parallel connection setup changes the way the battery cluster connects to the power conversion system (PCS) from DC parallel to AC parallel. The PCS and the battery cluster are set up in a "one-to-one" manner, which improves control accuracy by switching from multiple battery clusters to just one.
LERETECH offers a highly efficient cooling solution with a free cooling module, which can be used in either a centralized cooling plant or connected to individual battery containers. This cooling system is adaptable to various climate conditions. When compared to traditional methods, our solution can enhance RTE by up to 2%.
DC side parameter | |
---|---|
Chemistry | LFP |
Configuration | 12P416S |
Nominal voltage | 1331.2Vdc |
Voltage range | 1164.8~1497.6Vdc |
Battery capacity | 5013kWh |
Cycle life | >8000 cycles |
Rated power | 2500 kW |
System parameter | |
Cooling | Liquid cooling |
Operating temperature | -30℃~55℃ |
Humidity | 5~95%, without condensation |
Altitude | ≤3000m |
Weight | 42t |
Dimensions | L6458*W2600*H2896mm |
IP Rating | IP54 |
System cycle efficiency | ≥94%(patented technology can be ≥97%) |
Fire protection system | Pack-level fire protection,aerosol,NOVEC,active early warning |
Compliant with standards | IEC/EN 61000-6-2, IEC/EN 61000-6-4, EN 50549-1 |